The correct option is (c) Leakage reactance and armature reaction
Explanation: The leakage inductance Lc of the coil undergoing commutation has induced in it reactance voltage Lc (dic/dt) which opposes the change in current thereby delaying commutation. The effect of armature reaction causes shift in MNA, delaying the whole commutation process ultimately.