Correct option is (d) Abrasion from dust, excessive spring pressure and rough commutator bars
To explain I would say: Brushes undergo various forces due to their location in a DC machine, they are in contact with rotating and stationary part of the machine. Hence, rough contact between commutator and brushes, inappropriate pressure on brush to rotating part may affect quality of commutation process.