What should be the armature mmf per pole for output over 1500 kW?

(a) 5000 A

(b) 5000-7500 A

(c) 7500-10000 A

(d) upto 12500

This question was addressed to me during a job interview.

My query is from Selection of Number of Poles topic in section Thermal Design Aspects of Electrical Machines & D.C of Design of Electrical Machines

1 Answer

0 votes
by (1.4m points)
selected by
 
Best answer
The correct choice is (d) upto 12500

The explanation: 5000 A is for output of about 100 kW. 5000 to 7500 A for output voltage of 100 to 500 kW. 7500 to 10000 A is for the output of 500 to 1500 kW.

Related questions

Welcome to TalkJarvis QnA, a question-answer community website for the people by the people. On TalkJarvis QnA you can ask your doubts, curiosity, questions and whatever going in your mind either related to studies or others. Experts and people from different fields will answer.

Most popular tags

biology – class 12 biology – class 11 construction & building materials chemistry – class 12 electronic devices & circuits network theory data structures & algorithms ii cell biology ic engine insurance finance money computational fluid dynamics engineering physics i discrete mathematics chemistry – class 11 aerodynamics casting-forming-welding i engineering mathematics operating system casting-forming-welding ii engineering drawing mysql engineering geology digital circuits wireless mobile energy management electrical measurements digital communications cyber security analytical instrumentation embedded systems electric drives cytogenetics computer fundamentals life sciences basic civil engineering advanced machining iot design of electrical machines physics – class 12 applied chemistry dairy engineering basic chemical engineering cloud computing microprocessor bioinformatics aircraft design aircraft maintenance software engineering drug biotechnology digital signal processing biochemistry data structures & algorithms i automotive engine design avionics engineering material & metallurgy energy engineering cognitive radio unix electrical machines biomedical instrumentation object oriented programming electromagnetic theory power electronics analog communications bioprocess engineering civil engineering drawing engineering metrology physics – class 11 mathematics – class 12 engineering chemistry i basic electrical engineering unit processes mongodb signals and systems cryptograph & network security hadoop mathematics – class 11 engineering physics ii html control systems engineering mechanics antennas analog circuits computer network java sql server javascript concrete technology chemical process calculation artificial intelligence design of steel structures c++ database management computer architecture engineering chemistry ii corrosion engineering chemical technology dc machines
...