Correct choice is (d) 750 HV
Best explanation: Gauging surfaces of plain plug gauges are suitably stabilized, lapped and ground. These surfaces are normally hardened to not less than 750 HV. For sizes up to 63 mm, double ended type of plug gauges are used, and for above 63 mm single ended are used.